Fluid Power World

  • Home
  • Technologies
    • Hydraulics
      • Cylinders & Actuators
      • Filtration/Contamination Control
      • Fittings, Couplings & Adapters
      • Fluids
      • Fluid Conditioning
      • Hose & Tubing
      • Pumps & Motors
      • Related Technologies
      • Sealing
      • Sensors & Gauges
      • Valves & Manifolds
    • Pneumatics
      • Air Preparation & Regulation
      • Compressed Air Technologies
      • Cylinders & Actuators
      • End Effectors & Grippers
      • Fittings, Couplings & Adapters
      • Hose & Tubing
      • Sensors
      • Vacuum
      • Valves & Manifolds
  • Engineering Basics
  • Trending
  • Resources
    • Digital Issues
    • Pneumatics Tech Toolbox
    • Podcasts
    • Subscribe to Fluid Power World Print Magazine
    • Videos
    • Webinars / Digital Events
    • White Papers
  • Women in Engineering
    • Women in Fluid Power
    • Women in Engineering
  • Design Guide Library
  • Classrooms
    • Pneumatics Classroom
  • SUBSCRIBE

EHAs and energy efficiency

By Ken Korane | November 27, 2019

Share

In our recent hydraulics design series, we’ve looked at how to improve and enhance circuits and systems with an eye toward reducing complexity, lowering costs and improving overall efficiency. Here are a few comments on the effects of some specific types of components discussed, as well as options engineers need to consider in terms of overall system performance.

A primary focus throughout the series (listed below) is on actuators like hydraulic motors. Take, for example, the circuit discussed in “How to improve hydraulic motor drives” that delved into the nuances of hydraulic motor two-speed drives. The concept circuit, shown below, would work equally well for a double-rod cylinder or single-vane rotary actuator as long as flows are symmetric.

Alternative circuit for two-speed actuators

At first glance, the two-speed motor circuit appears to be extremely inefficient. During high-speed, low pressure operation, energy will be lost through the 4-way LP/HS valve and motors 3 and 4, even though each of these devices would be operating near optimal design efficiency.

For instance, assume Unit 3 is a bent-axis piston motor with around 94% overall efficiency; Unit 4 is a large low-pressure gear or vane-type unit that offers efficiency of approximately 85% under ideal conditions; and the 4-way LP/HS valve is a typical D05 size that operates at a fraction of Unit 4’s flow with throttling losses of approximately 3%.

Combining these losses gives a transmission efficiency of 0.94 × 0.85 × 0.97 = 0.77. Accounting for internal leakages and torque losses, perhaps a final result would be closer to 75% efficiency, and this does not include losses from Unit 1, Unit 5 and various plumbing lines and connections.

A more-traditional circuit might have 4-way valve losses of 8 to 10%, which is better than the 25% loss through the two-speed design. But it would have a typical axial-piston pump that operates near 75% efficiency at low pressure. More importantly, without the two-speed drive circuit, Unit 1 would be oversized for the working cycles of all other actuators, which results in further efficiency loss.

As another option, engineers can consider a completely different approach to better efficiency: all of the hydraulic motors discussed throughout the article series could be replaced with electric motors and VFDs. This would allow rotation reversal of the low-pressure, high-volume (LPHV) pumps. Depending on motor/VFD size, this may have a similar overall cost to the hydraulic motor design.

A single VFD can run multiple electric motors, as long as they can be operated sequentially and not simultaneously. This means the VFD can bring Unit 1 (the primary pump) to a stop, then accelerate the LPHV pumps by switching to control a separate electric motor. Efficiency would be much improved in this case. During LPHV operation, there would no losses from Unit 1, no valve losses, and no hydraulic motor losses.

The obvious downside is response time. Standard induction motors may require several seconds to reach full speed. However low-inertia motors can fully reverse rotation in under 200 msec, even for motor sizes greater than 100 hp. A related downside is deceleration time. Near the end of stroke (either extend or retract), the LPHV pumps must stop rotating. Load braking of the electric motor will occur due to rapid pressure rise. At this point, the VFD must be commanded to switch control to the motor of Unit 1.

To read previous stories in this hydraulic-design series, see:
Design concepts for open-circuit architectures
Flow amplification limits valve losses
Regenerative concepts for flow amplification
What are opposite-phased cylinders?
How to improve hydraulic motor drives


Filed Under: News, Pumps & Motors

 

Current Digital Issue

  Easier access to more of our content Every other month, readers of Fluid Power World have access to our beautiful print and digital editions, where we share a selection of the best fundamentals content, technology news, case studies, and technical articles that cover the gamut of hydraulics and pneumatics system design. But we only…

Subscribe!

Fluid Power World is written by engineers for engineers engaged in designing machines and or equipment in Off-Highway, Oil & Gas, Mining, Packaging, Industrial Applications, Agriculture, Construction, Forestry, Medical and Material Handling. Fluid Power World covers pneumatics, mobile hydraulics and industrial hydraulics.

Fluid Power Design Guides

fluid
“fpw
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for Fluid Power Professionals.

RSS Featured White Papers

  • Moving fluid power forward
  • High-force linear motion: How to convert from hydraulic cylinders to electric actuators and why.
  • A technical comparison: Performance of pneumatic cylinders and electric rod actuators
Fluid Power World
  • Hose Assembly Tips
  • Mobile Hydraulic Tips
  • Pneumatic Tips
  • Sealing & Contamination Control Tips
  • About us
  • Contact Us

Copyright © 2024 WTWH Media LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media
Privacy Policy | Advertising | About Us

Search Fluid Power World

  • Home
  • Technologies
    • Hydraulics
      • Cylinders & Actuators
      • Filtration/Contamination Control
      • Fittings, Couplings & Adapters
      • Fluids
      • Fluid Conditioning
      • Hose & Tubing
      • Pumps & Motors
      • Related Technologies
      • Sealing
      • Sensors & Gauges
      • Valves & Manifolds
    • Pneumatics
      • Air Preparation & Regulation
      • Compressed Air Technologies
      • Cylinders & Actuators
      • End Effectors & Grippers
      • Fittings, Couplings & Adapters
      • Hose & Tubing
      • Sensors
      • Vacuum
      • Valves & Manifolds
  • Engineering Basics
  • Trending
  • Resources
    • Digital Issues
    • Pneumatics Tech Toolbox
    • Podcasts
    • Subscribe to Fluid Power World Print Magazine
    • Videos
    • Webinars / Digital Events
    • White Papers
  • Women in Engineering
    • Women in Fluid Power
    • Women in Engineering
  • Design Guide Library
  • Classrooms
    • Pneumatics Classroom
  • SUBSCRIBE